Showing results: 61 - 75 of 141 items found.
-
Suzhou 3ctest Electronic Co.,Ltd.
coupling/decoupling network is to test the capacity of high speed communication line for surge test. Data transmission rate is up to 1,000MBit/s. It is designed to meet the requirements of figure 14 in IEC/EN 61000-4-5: 2005. The material of decoupling device is high conductive magnetic material. Stable decoupling capacity and transmission rate, easy to use and compact size.
-
EMI-9KC/EMI-9KB -
Lisun Electronics Inc.
EMI-9KB is an automatic EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem. The test results are according to the international format test report. The EMI Test System EMI-9KB fully meets CISPRl6-1, GB17743, FCC, EN55015 and EN55022.
-
DX-101 -
Dexing Magnet Tech. Co., Ltd
DX-101 Gaussmeter is based on the Hall effect magnetic field strength of the latest developments in instrumentation, the design of desktop-type Gauss meter. Maximum range 330.0mT and 3000mT two tranches, the minimum basic error of 1.0%. Test probe connectors is imported, stable and reliable connection.
-
Model SST500X500 -
Gopal Electronics
Gopal Make single sheet tester SST is developed as per IEC 60404-3. It can be attached as probe to Ep400 Main unit and user can test specific total loss, specific apparent power, and r.m.s value of magnetic field strength as well as B/h curve in the software.
-
RMO-H -
Amperis sl
The RMO-H is a portable, battery-operated micro-ohmmeter based on state-of-the-art technology, using the most advanced battery mode and switching technique available today. The high-capacity Li-Po battery allows the generation of a ripple-free DC current of up to 300 A. The test current is user-selectable and generated in an automatically regulated test ramp. During the test, the RMO-H increases the current before the measurement and decreases it afterwards. This significantly reduces magnetic transients.
-
138 -
Electronic Specialties Inc.
*54" Test Lead Set *Mag Lead features a magnetic disconnect. *You can "stick" to any metallic ground or test point. *Time saving product - can substitute for alligator clips at metallic test points. *Now, when you need alligator clips, you've got them! *Fits almost all DMM's and hand held scopes. *Get the Mag Lead, it stays put and won't fall off!
-
Teslameter M-Test LL -
Maurer Magnetic AG
Measure residual magnetism on ferromagnetic materials precisely and reliablyquick detection of residual magnetismreproducible measurement results through automatic storage of the maximum valuesdefined measuring distance of 0.5 mm from the Hall probe to the measuring surfacemeasuring static and alternating magnetic fieldsselectable units: A / cm, Gauss, mTwear-resistant test sample
-
Supreme Instrument Laboratories
The two voltage vectors, one from Standard Potential Transformer and the other from the Potential Transformer under test energies the high permeability magnetic core and then associated windings try to annual the residual magnetism which occurs due to error. The differential vectors will be proportional to phase error and ratio error magnitudes.
-
LP Series -
Hsiang Cheng Electric Corp
*High accuracy 0.07% rd + 0.03% ro*Excellent long term stability*Outstanding over capability and temperature performance*Wide selection of input / output ranges*Meets ANSI C37.90 (1989) and BEAMA No. 219 tests*High magnetic field immunity*Real power - able to measure distorted waveform
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
The Eastern Specialty Company
UtiliShelf® (Catalog No. 1063) allows you to create a quick and easy work station at a site. The UtiliShelf® is magnetic and will attach to any metal object (16 gauge or thicker for full magnet strength). No more worrying about where you’ll be setting up your test equipment or laptop in the field!
-
KT-200SG -
Kast Eng Co. LTD.
This test instrument stands for the EMI(Electro Magnetic Immunity) ability test to the electric devices, electronic circuit boards & electric equipments. Recently this instrument is widly used in many companies in Korea & other countries to test the immunity to thier products-power supply, drive PCBs, communication systems, LCD display panels whether they are safe or not against the impulse & noise.All for the purpose, of this object, it generates 4 ~ 5 kinds of different impulse test waveforms.Output test voltage level : 5 ~ 200 V ImpulseOutput voltage polarity : Positive, NegativeType of waveforms
-
Fieldpiece Instruments, Inc
A classic style multimeter with True RMS and phase rotation. This manual ranger covers the electrical parameters you need for HVACR and, with detachable test leads, works with our accessory heads to test non-electrical parameters too. The LT16A meter measures current, resistance, voltage, capacitance, frequency, continuity and more. Test leads store in the meter body along with the tilt stand and magnetic hanger. The body is constructed of durable ABS plastic and a blue backlight makes the large LCD even more visible.
-
SE -
Xitron Technologies Inc.
Safety First! Vitrek’s SE Series of high voltage safety enclosures are designed to prevent the potential of electrical shock when performing electrical tests. The enclosure comes standard with a magnetic safety interlock switch and chassis ground connection that must be wired from the safety tester to the safety enclosure by the end customer for safe operation.
-
Lisun Electronics Inc.
EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem.